General operation method of solid phase extraction column

General operation of solid phase extraction
Reverse extraction column operation
Normal phase extraction column operation
Ion exchange extraction column
Extracted from polar matrix
Non-polar samples
Extracted from non-polar matrix
Polar samples
Extract charged samples
activation
Rinse the extraction column with 3-5 ml of methanol;
Rinse the extraction column with 3-5 ml of deionized water (or buffer) and keep the extraction column moist
3-5ml non-polar solvent
Elution extraction column
Rinse the extraction column with 3-5 ml of deionized water and / or low ionic strength buffer
Loading
Sample at the appropriate flow rate
Evenly through the extraction column
With a low flow rate, the sample is evenly passed through the extraction column
Cleaning
An extraction column that elutes the adsorbed sample with 5 ml of a solvent of appropriate polarity (commonly used are pure water, buffer, water / organic solvent mixture)
Elute the extraction column with 5 ml of a suitable non-polar solvent
Rinse the extraction column with 5 ml of deionized water and / or low ionic strength buffer
Elution
The test sample is eluted in batches with 1-5 ml non-polar solvent to the collection container
The test sample is eluted in batches with 1-5 ml of polar solvent to the collection container
The test sample is eluted with 1-5 ml of high ionic strength buffer to the collection container