What factors should be paid attention to in the use of gas chromatograph

The gas chromatograph should pay attention to the following factors in use:

(1) Environmental conditions The gas chromatograph does not have strict requirements on the ambient temperature. Generally, it can be operated normally at room temperature of 5 ~ 35 ℃. However, the general requirement for the ambient humidity is 20% to 85%. In highly humid areas, when using the hydrogen flame ionization detector of some models, the insulation performance of the amplifier will be reduced due to high humidity. If you operate on a high sensitivity block, the response value will decrease. Analysts should take necessary measures if they encounter the above phenomena while using the instrument.

(2) The purity of the gas source used in the gas purity gas chromatograph must be above 99.99%. At present, many operators have not paid enough attention to the problem of different detectors requiring different gas source purity. In use, the detector may have high detection limits and unstable baseline due to insufficient gas source purity. For example, when hydrogen with a purity of 98% is used as the gas source of the hydrogen flame ionization detector, when it is used on the 104MΩ sensitivity block of the detector, the baseline may be seriously unstable due to insufficient hydrogen purity (containing flammable gases such as methane). , As if there are peaks that never end. If the purity of the carrier gas is not high and the trace oxygen is contained, it will affect the life of the capillary column.

(3) Selection of air flow ratio For the lower hydrogen flame ionization detector, N2-H2-Air flame is required, and it should be an oxygen-enriched flame after ignition, that is, the air should be excessive to ensure that the hydrogen is completely burned, the best ratio of the three gases N2: H2 = 1: (0.85 ~ 1), Air: H2 = (6 ~ 8): 1 or greater air volume. Under this condition, the detector has high sensitivity, good stability and reliable quantitative correction factors.

Clamshell is a creative packing method, it can be shaped in different kind of models. It is also easy to open the clamshell mold with inexpensive set up charge.

Plastic type: PP, PET, PVC...etc.

OEM and ODM designs are welcome.

MOQ: normally 5000set/design, or we can further discuss.

Sampling: if we have samples available, we're glad to send you free sample as long as you can offer us your courier number.

Certificate: our art sets are able to pass EN71 part 1 to part 3, Phthalate free, ASTM D-4236, CPSIA HR4040...etc.

Delivery: usually 35-40 days after approval of pre-production sample.

Payment terms: 30% TT deposit prepaid, 70% TT balance against BL copy.

Clamshell Stationery Set

Stationery Set,Clamshell Stationery Set,Plastic Clamshell Stationery Set,Stationery Plastic Clamshell Box

Ningbo Vinny International Trading Co., Ltd , http://www.vinnystationery.com